4720 Industrial Access Rd.
Douglasville, GA 30134
770-445-8923

Local Reviews
for lithia springs, ga

Rated 3.7 out of 5 stars based on 3 customer reviews

Horrible

Way overpriced for what needed to be done. They wanted to charge me $829. For labor. Called three other places and we’re $500 cheaper at each place.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Top notch service.

Incredible company. Customer Service and quality of servicemen is simply amazing. I would recommend Keith and his incredible staff to everyone.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Customer Service and Follow Up

The service I received from Dobbs was A-1. From the initial call, scheduling and end of service follow through, I received great communication and service. I was informed about the work needed, costs and there were no surprises! I am a very satisfied customer.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lithia springs, ga

Dobbs Technician A.

Dobbs Technician A. Job Checkin

Advised to put fan on auto so ac can dehumidify. 45 to 55 is normal. No dehumidifier in home.


Christian R.

Christian R. Job Checkin

Removed old equipment and installed new Rheem 4 ton 18 seer heat pump with 4 ton evaporator coil and 96% gas furnace. Installed new emergency drain pan, new pan safety switch, new coil safety switch, new condensation pump, new thermostat, new composite pad and new line voltage monitor for outdoor unit. Reconnected high voltage, low voltage, drain line, gas line, return plenum, supply plenum and exhaust vent. Tested system operations in heating and cooling, set refrigerant charge.


Keith D.

Keith D. Job Checkin

Quoted and emailed over in hvac biz pro


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Completed single system cooling maintenance, replaced filter, unit operating within factory specs at this time.


Keith D.

Keith D. Job Checkin

Quoted in hvacbizpro and emailed


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Arrived to system off, turned system in cool and checked refrigerant pressures found system is low 1-2lbs of R410A, indoor blower and coils are dirty, return duct has a restriction, condensate safety is not wired in, outdoor coils are dirty. If homeowner opted for leak searching and replacing indoor coil there is a possibility that this coil is out of stock due to the change in refrigerants. Spoke with Jerry he decided to have a comfort advisor come out and give quote on upgrading comfort system. System is 5 years old, checked warranty through weather king (brand) and found that system does not have a warranty. Recommend leaving system off to prevent indoor coils from freezing. OD temp 78


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Completed single system cooling maintenance. Checked filter, owner supplied. System operating properly at this time.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Indoor control board malfunctioning causing unit to periodically cut off. Board needs replaced filter. Unit is 15yrs plus, comfort specialist coming out to quote new system.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Called and left message


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Warranty variable speed condenser fan motor is faulty and failing, needs replacing. Maintenance paid. She said she will let us know. Estimate included.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Completed single system cooling maintenance on, replaced filters, operating properly at this time. Gave estimate for new thermostat and ss2 water safety


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Completed single system cooling maintenance on, replaced filter, unit operating within factory specs.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

Found flame sensor dirty causing the system to shut off. Offered homeowner maintenance plan for just heating he decided to do it. Found gas leak on gas line to furnace spoke with homeowner he decided to repair, repaired gas line and checked for leaks with meter and soap bubbles none found.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

DCM1:AC completed, changed 16x20x1 filter System is fully functional and operating within manufacturer specifications at this time. Refrigerant pressures and temperatures are appropriate for indoor and outdoor weather conditions.


Dobbs Technician A.

Dobbs Technician A. Job Checkin

DCM1: Ac Completed, Changed (1) 20x25x4 filter System is fully functional and operating within manufacturer specifications at this time. Refrigerant pressures and temperatures are appropriate for indoor and outdoor weather conditions.